To run OASIS3 in interpolator-only mode, one has to go through the
following steps (the following specific files can be
retrieved from CERFACS CVS only):
- Compile OASIS3 following the procedure described in section
8.1 specifying NONE as <mp>.
- Compile the programs that will calculate the
interpolation error fields, i.e. gen_error.f90 and
gen_error_vector.f90 in directory prism/util/running/testinterp/error.
- Execute the
running script prism/util/running/testinterp/sc_run_testinterp.
- The results obtained after running the TOYCLIM with the defaults
parameters should match the ones in prism/data/testinterp/outdata.
For more details, please read the prism/util/running/testinterp/README_testinterp.
Reinhard Budich